Live Member Webinar: Design Fire Scenarios for Hazard Assessment of Modern Passenger Vehicles

When:  Wed, Jul 30, 2025 from 11:00 to 12:00 (ET)

Join us for this upcoming webinar with Jonathan Hodges. Full-scale testing of battery electric (BEVs) and internal combustion engine (ICEVs) passenger vehicles has historically shown peak heat release rates (HRRs) ranging from 5-10 MW. However, the vehicles tested in these studies are smaller with less energy capacity than vehicles currently on the market. This presentation will present a recently developed model to extrapolate data from full-scale vehicle fire tests to evaluate the fire hazard associated with larger passenger vehicles. Data are used from 38 full-scale vehicle experiments in the public literature to develop and validate the model. The validated model is then used to develop conservatively bounding fire scenarios for vehicles representative of the current market environment. No significant difference was observed in the HRRs between the similarly sized ICEVs and BEVs in this work; however, the predicted HRRs for both vehicle types significantly exceeded existing design guidance. While the model may be shown to be overly conservative in future testing, it is validated using the data that currently exists, and points to an alarming trend in the fire protection industry, where the hazard posed by single-passenger vehicles may exceed existing design guidance.

Speaker:
Jonathan Hodges, PhD

For more information and to register, you can visit here.