This website uses cookies to store information on your computer. Some of these cookies are used for visitor analysis, others are essential to making our site function properly and improve the user experience. By using this site, you consent to the placement of these cookies. Click Accept to consent and dismiss this message or Deny to leave this website. Read our Privacy Statement for more.
Advanced Fire Alarm System Design Course- Session I: Applying the Principals of PBD
Share |

Description:

This two-day course presents a review of the performance-based design process and its applicability to the design of fire alarm systems. The course covers the developing of a stakeholder committee, refining performance objectives to concrete performance criteria, and developing performance equivalent alternative designs. Fire dynamics and the roll of fire modeling in the design process and design documentation are also addressed.

Learning Objectives

Upon completion of this course participants will be able to:

  • Understand the process of performance-based design and how it is applied to the design of fire alarm systems.
  • Understand the nature and character of fire and the associated products of combustion.
  • Analyze fire hazards.
  • Distinguish current technologies used to mitigate fire damage by proper design, construction, arrangement, and occupancy type of buildings.
  • Knowledge of how to mitigate fire damage by proper design, construction, arrangement and use of buildings.
  • Understand the basics of design, installation, and maintenance of fire detection and suppression communication systems.
  • Identify the factors that influence design and inputs from stakeholders and authority having jurisdiction.
  • Determine suitable detection methods and technologies to satisfy performance requirements.

Prerequisite

Successful completion of the NFPA Fire Alarm Code Course or equivalent knowledge. Basic computer skills, and basic knowledge of performance-based design. Know and apply fire and life safety codes and standards. Can read and understand basic construction drawings/technical documents.

Target Audience

Fire Protection Engineers (FPEs), Fire Alarm Designers, Code Officials, Plan Reviewers, Design Professionals (Architects/Engineers)

Materials

Participants should bring with them their own copies of NFPA 101®, Life Safety Code®; NFPA 72®, National Fire Alarm and Signaling Code®, and a scientific calculator.

Course Assessment

Participants will be assessed via a written exam upon completion of the course. A passing score of 70% will be required to obtain a Certificate of Completion.