This website uses cookies to store information on your computer. Some of these cookies are used for visitor analysis, others are essential to making our site function properly and improve the user experience. By using this site, you consent to the placement of these cookies. Click Accept to consent and dismiss this message or Deny to leave this website. Read our Privacy Statement for more.
Advanced Fire Dynamics Simulator and Smokeview
Share |

Description:

This workshop is a hands-on workshop on advanced techniques in using the Fire Dynamics Simulator (FDS) modeling and Smokeview visualization software. The course is intended for current users of FDS who are comfortable creating simple FDS input files from scratch without assistance. The course consists of many short modules covering specific topics. Each module includes a lecture section and a workshop section in which the student works example problems on a personal laptop computer.

Learning Objectives

Upon completion of this course participants will be able to:

  • Complex geometry
  • HVAC (Heating, Ventilation, Air Conditioning) networks
  • Tracking gas species through the domain
  • Implementing pre and post flashover fires
  • Pyrolysis modeling and flame spread
  • Advanced topics in combustion
  • Creating and removing obstructions
  • Smoke detectors and sprinklers
  • Grid transformations
  • Advanced Smokeview techniques: custom iso-surfaces, texture mapping, render files, and cad view
  • Basics of the Graphical User Interface program, PyroSim

 

Prerequisite

Successful completion of SFPE’s Introduction to FDS course or equivalent is a prerequisite for the advanced course. Each student should have an understanding of fire dynamics, heat transfer, and fluid dynamics theory to gather the greatest understanding possible from the course. Each student should be able to develop FDS input files, develop design fire scenarios, and review FDS results using Smokeview without assistance.

Target Audience

FPEs, Code Officials, Facility Engineers, Plan Reviewers, Design Professionals (Architects/Engineers)

Materials/Requirements

Attendees must bring a laptop computer with a minimum 1 GB of RAM and 10 GB of free hard disk space. The computer should have a spreadsheet program for analyzing data and Adobe Acrobat for reading the documentation. The attendees should also make sure that they have sufficient security privileges on their computers to allow the software to be installed during class.

Before coming to class, attendees should have download the most recent version of FDS and Smokeview software from the NIST website and make sure the programs run on their computer. The NIST website is http://www.bfrl.nist.gov. Follow the links for software, fire simulation software, and the NIST Fire Dynamics Simulator and Smokeview.

Course Assessment

Upon completion of a test attendees will be awarded a certificate of attendance.

Corporate 100 Visionaries

About Us

© 2019 SFPE | All Rights Reserved
Privacy Policy