Seminars







Pre-Conference In-Person Seminars

Please join us for live instructor-led in-person seminars prior to the conference. These SFPE seminars were developed, and peer-reviewed by SFPE experts and provide in-depth education on selected topics.

After registering for the conference, you’ll receive a confirmation email with a discount code for $100.00 off the Principles of Fire Protection Engineering seminar and $75.00 off the Substantiating the Suitability of a Fire Model seminar in Edinburgh. You or a colleague can use this code to register via our learning management system. Separate registration allows SFPE to provide course materials, assessments, references, and links that instructors will share during the class. Approximately two weeks before the conference, all seminar registrants will receive an email with detailed onsite logistics and course information.

Early Bird Registration ends on 28 February 2025—register early to secure the discounted rate!
____________________________________________________________________________________________________

Seminars:

This course presents the application of science and engineering principles to protect people, property, and their environments from the harmful and destructive effects of fire and smoke. It covers areas of fire detection, suppression, mitigation, and human behavior and recommendations on maintaining a tenable environment for evacuation during a fire scenario.

Professional Development Credit: 15 PDH

Instructor: William "Bill" Koffel, PE, FSFPE

William "Bill" Koffel, PE, FSFPE is President and founder of Koffel Associates, Inc. He is recognized as an expert in the fire protection and life safety aspects of codes and standards.

Bill Koffel is Director, Undergraduate FPE Online Program at the University of Maryland. With the introduction of online courses, the only ABET accredited BS in Fire Protection Engineering will be attainable via an online modality. Bill remains active in the development process of the industry's governing codes, standards and design guidelines including International Code Council (ICC), NFPA, Society of Fire Protection Engineers (SFPE) and Underwriters Laboratory (UL). He is a member of many NFPA Technical Committees. He is a member of the Board of Visitors, Department of Fire Protection Engineering, University of Maryland and a Past President of the SFPE.

This one and a half day course delves into the critical process of model substantiation in the field of engineering, focusing on fire models and their evolving capabilities. Participants will gain an understanding of the key steps in model substantiation, covering problem definition, model selection, and verification and validation processes. The course emphasizes recognizing criteria for evaluating fire models, assessing factors influencing model choice, and navigating project constraints in the selection process. Participants will also become proficient in applying the Fire Model Substantiation Flow Chart and understanding the intricate relationship between initial and boundary conditions. The course addresses strategies for handling uncertainty in fire modeling and provides a high-level overview of modeling types, including their assumptions, limitations, and unique advantages and disadvantages. Notably, the course does not offer instruction on specific modeling software, methods, or tools. 

Professional Development Credit: 11 PDH

Instructor: Bryan Klein

Bryan Klein is the Product Manager at Thunderhead Engineering. He is also an instructor and content developer for SPFE courses and serves on the Board of Governors for the SFPE Foundation.

Seminar Pricing:

Seminars

Dates/Times

PDH

Early-bird Discounted Pricing

(Until 28 February)

Member/ Non-member

Regular Pricing 

(Starting 1 March)

Member/ Non-member

 Principles of Fire Protection Engineering*

2 Day Course

7-8 April: 9:00 - 17:00

15

$999 USD/ $1,274 USD

$1,099 USD/ $1,349 USD

 Substantiating the Suitability of a Fire Model*

1.5 Day Course

7-8 April: Monday 13:00 - 17:00, Tuesday 09:00 - 17:00

11

$699 USD/ $869 USD

$769 USD/ $939 USD

*Included in pricing: Handouts, Complimentary Lunch, Networking reception on Tuesday evening, and SFPE Certificate of Completion.

Venue Information:

Sheraton Grand Hotel and Spa Edinburgh - 1 Festival Sq, Edinburgh EH3 9SU, UK

SFPE attendees will enjoy a discounted room rate of £230/night for single occupancy and £250/night for double occupancy through 05 April. Rates are inclusive of full Scottish breakfast served within One Square dining room. Please review the hotel page for details and exclusive booking link.

Please note: SFPE reserves the right to cancel a seminar up to two weeks before the event. 

Questions? Contact us at education@sfpe.org