Deducing the Impact of Excluding Social Groups When Modelling Pedestrian Flow
By S.M.V. Gwynne and A.L.E. Hunt
For practical applications, it is often necessary to make broad assumptions when modelling pedestrian movement. Depending on the purpose of the model, certain factors may be simplified or excluded. These assumptions may be required to represent the scenario or focus on specific user objectives for technical or technological reasons. However, it is critical for those using people-movement models to understand the impact of underlying assumptions. This is important for any kind of pedestrian flow model: Whether it is mathematical, regulatory, experimental or computational, it is a simplification and requires leaving out real-world factors.1 These omissions and simplifications must be identified and justified, and the impact of their exclusion assessed.
This is challenging. Often, a factor is excluded or simplified because its impact is deemed negligible and/or undesirable. However, it is dangerous to underestimate the impact of a specific factor without close scrutiny, especially as the real-world scenario becomes more complex or dynamic, and the impact less intuitive.
This article presents a simple deductive approach to understanding the implications of excluding a particular factor: the presence of social groups in flow. This approach could be a useful tool to help explore the significance of other behavioural factors when designing models. Ideally, such deduction is already applied informally when developing models and scenarios, but the more-formal application might produce more-transparent documentation of modelling decisions.
Example Hypothesis
This article addresses the exclusion of social groups (formed from existing or emerging social ties) when modelling large-scale pedestrian flows, assuming that this effect is dominated by physical factors. Here we deduce the impact of social groups on pedestrian flow from stated premises2-9 by comparing a population of individuals and a population of social groups.
There has been research on the impact of social groups on people movement10-14 (e.g., on group longevity in emergency and influence on movement), but fewer attempts to explicitly model social groups.4, 15-22 There has been significantly more modelling of the impact of physical factors on crowd flow.18-19, 23-27
We have drawn conclusions from a set of accepted premises to demonstrate the reasonable application of this logic. The purpose of this analysis is to decide whether this is a factor that should be excluded from a model.
Premises
[P1] Individuals have different speeds (v) based on their physical attributes.23, 28 Given that movement is not constrained by the surrounding population or physical conditions, individual speeds vary between vmin and vmax, producing a range of speeds, RI = vmax-vmin, assuming vmin > 0 (i.e., that there is movement).
Individuals and Groups. Orange outlines indicate group membership.
[P2] Social groups exist in pedestrian flows.1-22 These groups may be of different sizes, demographics and configuration. Group members try to ensure the group remains intact by moderating their speed; i.e. traveling at the speed of the slowest group member (given [P1]).
[P3] Each group moves at the speed of its slowest group member (given [P2]). The range of group speeds within a population consisting only of social groups (or a sub-population within a flow), RG= [max{G1min,…Gnmin} – min {G1min-Gnmin}], where G1min is the minimum travel speed of a member of G1, etc.
RI > RG unless: (1) population density dictates movement so the population can reach a velocity (vρ) where vP<min(vmin)</min(v(i.e., achievable speed is less than the minimum individual speed); (2) every individual has the same speed (contradicting [P1]). [P3] implies that speed varies more in a flow of individuals (FI) than in a flow of groups (FG).
Social grouping through speed modification.
Purple arrows indicate possible speeds; red arrows, selected speeds.
[P4] If FI and FG start in the same initial configuration, then FI will have more potential to spread out over time while continuing to move towards the same target (all other things being equal) than FG given [P3]; i.e. RI > RG. This is true until the population density completely dictates the individual’s ability to select a travel speed; i.e., when vρ<min(vmin)</min(v. This also suggests that in mixed populations (individuals and groups), there is more opportunity for individuals to move away from slower-moving groups, assuming that their range of individual speeds is typically greater than that of groups. Therefore, it is possible that sub-populations of predominantly groups or predominantly individuals might develop within a larger flow.
[P5] FI will be formed from a lower-density (more distributed) population (DI) unless physically constrained (given [P4]). DI will enable continued higher speeds given that (1) individuals are not constrained by the slowest group member and (2) the population is more distributed, reducing the effective population density.9, 23, 27 FG will be formed from a higher density (less distributed) population (DG). DG will enable continued lower speeds given (1) that individuals are constrained by the slowest group member and (2) that the population is subject to a higher population density. Therefore, vI (the velocity produced during DI) should be greater than vG (the velocity produced during DG), all other things being equal.
[P6] Flow is a function of velocity, population density and effective width.23, 27 The implication of [P1–P5] is that until population densities dictate movement (i.e., when vρ<min(vmin)</min(v):
FI = vI*DI*w
FG = vG*DG*w
where vI is the velocity of the flow of individuals and vG is the velocity of the flow of groups. From above [P5]:
vI > vG
Dl<dG </d
Implications
This implies that (1) if a flow is formed only from groups (FG), then it will move more slowly than flows formed only of individuals (FI): vI > vG; and (2) FG moves at higher densities (Dl<dG </d <d)</d given that they move within a smaller range of velocities (RI > RG) that are less-distributed. FI will travel more quickly (as vI > vG), but at lower population densities (Dl<dG </d <d)</d . Conversely, FG will travel more slowly at higher densities, possibly producing similar flow levels. (FG) is more likely to experience higher congestion for longer periods, potentially leading to elevated levels of discomfort and physical interaction.
Although FI and FG produce different underlying conditions, they may result in similar aggregate conditions – notably, similar flow rates (on average, or at a point in time), where FI ≈ FG . This may lead underlying differences to be obscured.
This means that flow in a population consisting primarily of groups and flow in a population consisting primarily of individuals may appear similar (by measure), but the underlying conditions experienced may be very different.
Similar emerging conditions masking underlying dynamics
(comparing flow, f, against population density, ρ).
This analysis is true until densities dictate movement entirely (i.e., vP<min(vmin)</min(v. This analysis excludes numerous other factors that might contribute to the impact of social groups; e.g., passing through pinch-points, individual actions (people holding hands, people assisting others, group members attempting to form/reform a group, etc.). It is therefore possible that social groups have an even greater impact than that derived here.
Summary
This brief discussion outlines a simple deductive approach to exploring the impact of a modelling assumption — the differences in flows of individuals and flows of groups, based on speed moderation for group maintenance. Different underlying conditions in the population are deduced although these conditions may occasionally produce similar high-level flow outcomes.
A reader’s first response might be that this is speculative. It is. However, this speculation is intended to use broadly defensible initial premises to pose questions about the underlying assumptions when designing a model. These are questions that have to be addressed by modellers when documenting and justifying their assumptions.
We have examined extreme examples to demonstrate the point that flows purely of individuals and of groups produce different conditions. In reality, flows are likely to include individuals and groups.
The derived impact cannot be deduced to be uniform or static across time, scenarios or a population. It may be reasonable in some scenarios for modellers not to represent the impact of social groups; e.g., when population density determines the individual’s travel speed or when the number of groups in the population is sufficiently low.
There may be a threshold number or proportion of group numbers/types below which their impact is negligible. However, for large pedestrian flows, it is challenging to know this before analysis has been conducted and whether such conditions will be maintained uniformly throughout the population. For instance, sub-populations of groups might appear within a larger flow beyond this ‘threshold’ temporarily, even though it is reached globally.
In any case, our example shows that a high-level measure of flow may not sufficiently describe the conditions on a route if groups are present. When collecting data on the movement of large crowds, densities and group behaviours should also be considered. Afterward, a decision can be made about representing groups and other factors based upon an assessment of the expected impact.
For the practical use of people movement models, practitioners must understand the real-world factors that influence pedestrian performance. The factors that are included in their assessment should be reported and justified, along with those excluded. It is suggested that deductive approaches might help achieve this. It is argued here that the scale of the flow alone is not a robust justification for the exclusion of social group factors from modelling efforts. When considering this, and numerous other modelling decisions, similar deductive analysis can aid the modeller in assessing, documenting and explaining their assumptions and the scenarios examined.
S.M.V.Gwynne is with National Research Council Canada and A.L.E.Hunt is with Movement Strategies, London, UK.
References
1Gwynne, S.M.V., and Kuligowski, E.D.K., A Skeptic’s Discussion on Evacuation Modelling, Fire Protection Engineering, Q4, 76 (2017).
2Muller, F., and Schadschneider, A., Evacuation dynamics of asymmetrically coupled pedestrian pairs. In Traffic and Granular Flow 15, 265–272. Springer (2016).
3von Kruchten, C., Schadschneider, A., Empirical study on social groups in pedestrian evacuation dynamics. In Physica A: Statistical Mechanics and its Applications 475, 129–141 (2017).
4Oberhagemann, D., Konnecke, R., and Schneider, V., Effect of social groups on crowd dynamics: empirical findings and numerical simulations, Pedestrian and Evacuation Dynamics 2012, Springer, Berlin Heidelberg (2014).
5Vanumu, L.D., Rao, K.R., and Tiwari, G., Fundamental diagrams of pedestrian flow characteristics: A review, Eur. Transp. Res. Rev. 9:49. (2017).
6Seyfried, A., Steffen, B., and Lippert, T., Basics of Modelling the Pedestrian Flow. Phys A Stat Mech Appl 368 (1):232–238. (2006).
7Daamen, W., Modelling Passenger Flows in Public Transport Facilities. PhD Thesis, Delft University of Technology (2004).
8Tian, W., Song, W., Lü, W., and Fang, Z., Experiment and Analysis on Microscopic Characteristics of Pedestrian Movement in Building Bottleneck. SCIENCE CHINA Technol Sci 54(7):1730–1736. (2011).
9Kholshevnikov, V.V., Shields, T.J., Boyce, K.E., and Samoshin, D.A., Recent developments in pedestrian flow theory and research in Russia, Fire Safety Journal 43 108–118 (2008).
10Sime, J., Escape Behaviour in Fires: ‘Panic’ or Affiliation? PhD Thesis, Department of Psychology, University of Surrey. (1984).
11Jones, B.K., and Hewitt, J.A., Leadership And Group Formation In High-Rise Building Evacuations, Fire Safety Science-The Proceedings For The First International Symposium, Hemisphere Publishing Corp., Washington, 513–522 (1986).
12Johnson, N.,R., Feinberg, W.E., and Johnston, D.M., Microstructure and Panic: The Impact of Social Bonds on Individual Action in Collective Flight from the Beverly Hills Supper Club Fire, in Disaster, Collective Behaviour and Social Organisation (Eds: Dynes, R., and Tierney, K. (1994).
13McPhail, C., Stereotypes of Crowds and Collective Behaviour: Looking Backward, Looking Forward, originally presented to the ASA Section on Collective Behaviour and Social Movements' session, Miami, FL (August 1993).
14Aveni, A., The not-so-lonely crowd: friendship groups in collective behavior, Sociometry, vol. 40, 96–99 (1977).
15Gwynne, S., Galea, E.R., Lawrence, P.J. and Filippidis, L., Adaptive Decision-making in building Exodus in response to exit congestion, Proceedings of the 6th International Symposium IAFSS, ISBN: 0925 223 255, Poitiers, France (Ed.: M.Curtat), 1,041–1,052 (1999).
16Feinberg, W.E., and Johnson, N.R., Queuing, Exit-Sorting and Evacuation in Fire Emergencies: A Computer Simulation Investigation, Proceedings of the 1st International Symposium on Human Behaviour in Fire (Ed.: Shield, J.), Fire Engineering Research and Technology Centre, University of Ulster (1998).
17Gorrini, A., Crociani, L., Feliciani, C., Zhao, P., Nishinari, K., and Bandini, S., Social groups and pedestrian crowds: Experiment on dyads in a counter flow scenario. In Proceedings of the 8th International Conference on Pedestrian and Evacuation Dynamics - PED2016, Hefei, China, October 17–21, 2016, 179–184 (2016).
18Reuter, V., Bergner, B.S., Koster, G., et al., On modeling groups in crowds: empirical evidence and simulation results including large groups, Pedestrian and Evacuation Dynamics 2012, Springer, Berlin Heidelberg, 835–845 (2014).
19Bandini, S., Crociani, L., and Vizzari, G., An approach for managing heterogeneous speed profiles in cellular automata pedestrian models. J. Cellular Automata 12(5), 401–421 (2017).
20Schultz, M., Rossger, L., Fricke, H., and Schlag, B., Group dynamics behaviour and psychometric profiles as substantial driver for pedestrian dynamics, Pedestrian and Evacuation Dynamics 2012, Springer, Berlin Heidelberg[RET-C1] , 1,097–1,111 (2014).
21Xu, S., and Duh, H.B.-L., A simulation of bonding effects and their impacts on pedestrian dynamics, IEEE Transactions on Intelligent Transportation Systems, vol. 9, 153–161 (2010).
22Moussaıd, M., Perozo, N., and Garnier, S., et al., The walking behaviour of pedestrian social groups and its impact on crowd dynamics, PLoS ONE, 5.e10047 (2010).
23Gwynne, S.M.V., and Boyce, K.E., Engineering Data, SFPE Handbook of Fire Protection Engineering, 5th Edition (eds.: Hurley et al.), Springer, NY, 2,429–2,551 (2016).
24Batty, M., Agent-based pedestrian modelling. In Longley, P., and Batty, M. (eds.), Advanced Spatial Analysis: The CASA Book of GIS, 81–108. ESRI, New York (2003).
25Harney, D., Pedestrian modelling: current methods and future directions, Road & Transport Research 11(4), 2–12 (2002).
26Kuligowski, E.D., and Peacock, H.B.L., A Review of Building Evacuation Models, 2nd Edition (Rep. No. NIST TN 1680), NIST, Gaithersburg, MD (2010).
27Gwynne, S.M.V., and Rosenbaum, E.R., Employing the Hydraulic Model in Assessing Emergency Movement, SFPE Handbook of Fire Protection Engineering, 5th Edition, (eds.: Hurley et al.), Springer, NY, 2,115–2,151 (2016).
28Gorrini, A., Vizzari, G., and Bandini, S., Age and Group-driven Pedestrian Behaviour: from Observations to Simulations, Collective Dynamics 1, A3:1–16 (2016).